Efisiensi Penggunaan Energi Listrik pada Sistem HVAC (Heating, Ventilation, Air Conditioning) di PT. Seltechindo Servis

Saputra, Antoni (2020) Efisiensi Penggunaan Energi Listrik pada Sistem HVAC (Heating, Ventilation, Air Conditioning) di PT. Seltechindo Servis. Project Report. Universitas Internasional Batam. (Submitted)

[img]
Preview
Text
k-1721019-abstract-en.pdf

Download (1MB) | Preview
[img]
Preview
Text
k-1721019-abstract-id.pdf

Download (1MB) | Preview
[img] Text
k-1721019-bibliography.pdf

Download (286B)
[img]
Preview
Text
k-1721019-chapter1.pdf

Download (1MB) | Preview
[img]
Preview
Text
k-1721019-chapter2.pdf

Download (2MB) | Preview
[img]
Preview
Text
k-1721019-chapter3.pdf

Download (1MB) | Preview
[img]
Preview
Text
k-1721019-chapter4.pdf

Download (1MB) | Preview
[img] Text
k-1721019-chapter5.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[img] Text
k-1721019-chapter6.pdf
Restricted to Repository staff only

Download (2MB) | Request a copy
[img]
Preview
Text
k-1721019-chapter7.pdf

Download (1MB) | Preview
[img]
Preview
Text
k-1721019-cover-id.pdf

Download (16kB) | Preview

Abstract

Energi listrik merupakan sumber energi yang akan habis dan tidak dapat diperbaharui. Seiring dengan pertumbuhan industri semakin tinggi suatu negara pada zaman modern maka tingkat kebutuhan energi listrik akan semakin tinggi sehingga diperlukan upaya efisiensi dalam penggunaan energi listrik agar tidak terjadi pemborosan penggunaan energi listrik. Pada sektor industry, penggunaan energi listrik paling banyak terdapat pada sistem HVAC (Heating, Ventilation, Air Conditioning). Program efisiensi ini diterapkan pada sistem HVAC karena penggunaannya terbesar terdapat pada sistem ini. Program efisiensi ini bertujuan untuk mengurangi penggunaan energi listrik agar dapat tercipta Green Building pada perusahaan industri. Proses efisiensi yang dilakukan pada sistem HVAC dengan melakukan proses perbaikan atau improvement pada sistem HVAC khususnya pada chiller, melakukan optimasi set point temperature, dan melakukan proses management waktu untuk sistem HVAC agar semua sistem HVAC bisa mencapai efisiensi dalam penggunaan energi listrik. Campaign dan training kepada orang-orang yang terdapat di perusahaan untuk tidak menggunakan energi listrik secara berlebihan pada setiap equipment. Hasil implementasi untuk proses efisiensi energi listrik di tempat kerja praktek ini berhasil dilaksanakan dengan baik. Efisiensi listrik pada chiller sebesar 31,8% di Gedung A dan Gedung B sebesar 24,21%. Sistem HVAC setelah dilakukan efisiensi listrik dapat beroperasi secara normal tanpa mengurangi persyaratan fungsinya dan tercapainya High Performance Building yang ramah lingkungan. ********************************************************************** Electrical energy is a source of energy that will run out and can’t be renewed. Along with the higher industrial growth of a country in modern times, the level of electrical energy needs will be higher, so that efficiency efforts are needed in the use of electrical energy so that there is no waste of electricity usage. In the industrial sector, the most use of electrical energy is in the HVAC system (Heating, Ventilation, Air Conditioning). This efficiency program is applied to HVAC systems because the biggest use is in this system. This efficiency program aims to reduce the use of electrical energy in order to create Green Buildings in industrial companies. The efficiency process is carried out on the HVAC system by making improvements to the HVAC system, especially on the chiller, optimizing the set point temperature, and doing the time management process for the HVAC system so that all HVAC systems can achieve efficiency in the use of electrical energy. Campaigns and training for people in the company not to use excessive electrical energy on every piece of equipment. The results of implementation for the process of electrical energy efficiency in the workplace of this practice were successfully implemented. The electricity efficiency of the chiller is 31.8% in Building A and Building B is 24.21%. HVAC systems after electrical efficiency can operate normally without reducing the functional requirements and achieved environmentally friendly High Performance Building in industrial companies.

Item Type: Monograph (Project Report)
Additional Information: Similarity: 10
Uncontrolled Keywords: HVAC, Chiller, AHU, Set Point Temperature, Electricity Efficiency
Subjects: T Technology
Divisions: School of Industrial Technology > Electrical Engineering
SWORD Depositor: Admin Repository Universitas Internasional Batam
Depositing User: Admin Repository Universitas Internasional Batam
Date Deposited: 30 Apr 2020 07:21
Last Modified: 30 Apr 2020 07:23
URI: http://repository.uib.ac.id/id/eprint/2756