Floor Slab Analysis (Case Study: One Residence Apartment Batam Centre)

Astutik, Yayuk Setyaning (2018) Floor Slab Analysis (Case Study: One Residence Apartment Batam Centre). In: International Conference on Mechanical, Electronics, Computer and Industrial Technology (MECnIT 2018), 12-14 Desember 2018, Medan.

[img]
Preview
Text
2. Book of Abstarct MECnIT 2018.pdf

Download (2MB) | Preview

Abstract

Reinforced concrete slab are widely used in civil buildings, including as building floors, roof floors, bridge floors and dock floors. The load acting on the slab is generally calculated against gravitational loads. This study aims to analyse floor slab in the One Residence Batam Centre Apartment Construction Project. The moment method is used to predict the magnitude of frame and shrinkage values that refer to 2002 SNI. Loading is carried out from dead loads and live loads with a two-way reinforcement system. Reinforcement is done using steel with a diameter of 10 mm. So that the minimum area is 313 mm square with a distance of 250 mm and is in the safe category. From the calculation results obtained the concrete elastic modulus obtained by 250 Mpa with a reinforcement ratio of 0.0025. Checking the time dependency factor for dead loads is carried out within 3 months, 6 months, 12 months and more than 5 years. Long-term deflection due to frame and shrinkage is still in the safe category

Item Type: Conference or Workshop Item (Paper)
Uncontrolled Keywords: Floor Slab, Moment Method, Magnitude of Frame, Shrinkage
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TH Building construction
Divisions: School of Civil Engineering and Planning > Civil Engineering
Depositing User: Admin Repository Universitas Internasional Batam
Date Deposited: 08 Aug 2019 16:14
Last Modified: 08 Aug 2019 16:14
URI: http://repository.uib.ac.id/id/eprint/1386